Serial cable for multiple pumps - SER-P-n |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| SKU (Product Code): SER-P-n Serial cable for party hookup with n pumps | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| ( Manufacturer ) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
$40.00
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ask a question about this product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Multi pump setupMultiple pumps can be controlled from a single serial port using a combination of RS‑232 and RS-485 serial communication. The first pump is called the host and it is connected to the computer via RS-232. The MicroLynx is configured to communicate over RS-232 with the following communications settings: 9600 baud, No parity checking, 8 data bits, 1 stop bit, and no flow control. The MicroLynx is equipped with two communications ports on the communications connector and when this controller is set up as a host, it echoes all serial communication to its second RS-485 port. Additional controllers can be daisy chained on the RS-485 loop. Of course, each controller must be configured with a different address. The easiest way to do this when you want to link seven or less pumps is to set the dip switches on the controllers for the desired address. The following table shows the dip switch settings for devices A through G. To connect more than 7 controllers, you must use the DN command which is described in more detail in the MicroLynx manual.
When you set any of the dip switches, the PARTY mode variable for that controller will automatically be set to TRUE to indicate that all further communications must occur in Party mode. There are two distinctive components to Party mode communication.
Note: when ever you start typing all controllers except the one whose address has been typed stop interpreting the typed characters until the line feed is entered. So if you type an invalid command or address you must type Ctrl-J to “get the attention” of all the controllers. The cable that connects the multiple controllers will have the following pin-outs. Controllers 2 through n are all connected in the same way to Controller 1. This table also sets out the values of certain important settings on each controller.
Procedure
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||